update measurement_concept_Id text

closes #638
This commit is contained in:
Clair Blacketer 2024-04-12 12:10:18 -04:00
parent f9ebc22848
commit 4aaf0140c5
2 changed files with 2 additions and 2 deletions

View File

@ -142,7 +142,7 @@ device_exposure,device_source_value,No,varchar(50),"This field houses the verbat
device_exposure,device_source_concept_id,No,integer,"This is the concept representing the device source value and may not necessarily be standard. This field is discouraged from use in analysis because it is not required to contain Standard Concepts that are used across the OHDSI community, and should only be used when Standard Concepts do not adequately represent the source detail for the Device necessary for a given analytic use case. Consider using DEVICE_CONCEPT_ID instead to enable standardized analytics that can be consistent across the network.",If the DEVICE_SOURCE_VALUE is coded in the source data using an OMOP supported vocabulary put the concept id representing the source value here.,No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA device_exposure,device_source_concept_id,No,integer,"This is the concept representing the device source value and may not necessarily be standard. This field is discouraged from use in analysis because it is not required to contain Standard Concepts that are used across the OHDSI community, and should only be used when Standard Concepts do not adequately represent the source detail for the Device necessary for a given analytic use case. Consider using DEVICE_CONCEPT_ID instead to enable standardized analytics that can be consistent across the network.",If the DEVICE_SOURCE_VALUE is coded in the source data using an OMOP supported vocabulary put the concept id representing the source value here.,No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA
measurement,measurement_id,Yes,integer,The unique key given to a Measurement record for a Person. Refer to the ETL for how duplicate Measurements during the same Visit were handled.,"Each instance of a measurement present in the source data should be assigned this unique key. In some cases, a person can have multiple records of the same measurement within the same visit. It is valid to keep these duplicates and assign them individual, unique, MEASUREMENT_IDs, though it is up to the ETL how they should be handled.",Yes,No,NA,NA,NA,NA,NA measurement,measurement_id,Yes,integer,The unique key given to a Measurement record for a Person. Refer to the ETL for how duplicate Measurements during the same Visit were handled.,"Each instance of a measurement present in the source data should be assigned this unique key. In some cases, a person can have multiple records of the same measurement within the same visit. It is valid to keep these duplicates and assign them individual, unique, MEASUREMENT_IDs, though it is up to the ETL how they should be handled.",Yes,No,NA,NA,NA,NA,NA
measurement,person_id,Yes,integer,The PERSON_ID of the Person for whom the Measurement is recorded. This may be a system generated code.,NA,No,Yes,PERSON,PERSON_ID,NA,NA,NA measurement,person_id,Yes,integer,The PERSON_ID of the Person for whom the Measurement is recorded. This may be a system generated code.,NA,No,Yes,PERSON,PERSON_ID,NA,NA,NA
measurement,measurement_concept_id,Yes,integer,"The MEASUREMENT_CONCEPT_ID field is recommended for primary use in analyses, and must be used for network studies.","The CONCEPT_ID that the MEASUREMENT_SOURCE_CONCEPT_ID maps to. Only records whose SOURCE_CONCEPT_IDs map to Standard Concepts with a domain of ""Measurement"" should go in this table.",No,Yes,CONCEPT,CONCEPT_ID,Measurement,NA,NA measurement,measurement_concept_id,Yes,integer,"The MEASUREMENT_CONCEPT_ID field is recommended for primary use in analyses, and must be used for network studies. This is the standard concept mapped from the source value which represents a measurement.",The CONCEPT_ID that the MEASUREMENT_SOURCE_VALUE maps to. Only records whose source values map to concepts with a domain of ÒMeasurementÓ should go in this table.,No,Yes,CONCEPT,CONCEPT_ID,Measurement,NA,NA
measurement,measurement_date,Yes,date,Use this date to determine the date of the measurement.,"If there are multiple dates in the source data associated with a record such as order_date, draw_date, and result_date, choose the one that is closest to the date the sample was drawn from the patient.",No,No,NA,NA,NA,NA,NA measurement,measurement_date,Yes,date,Use this date to determine the date of the measurement.,"If there are multiple dates in the source data associated with a record such as order_date, draw_date, and result_date, choose the one that is closest to the date the sample was drawn from the patient.",No,No,NA,NA,NA,NA,NA
measurement,measurement_datetime,No,datetime,NA,"This is not required, though it is in v6. If a source does not specify datetime the convention is to set the time to midnight (00:00:0000)",No,No,NA,NA,NA,NA,NA measurement,measurement_datetime,No,datetime,NA,"This is not required, though it is in v6. If a source does not specify datetime the convention is to set the time to midnight (00:00:0000)",No,No,NA,NA,NA,NA,NA
measurement,measurement_time,No,varchar(10),NA,This is present for backwards compatibility and will be deprecated in an upcoming version.,No,No,NA,NA,NA,NA,NA measurement,measurement_time,No,varchar(10),NA,This is present for backwards compatibility and will be deprecated in an upcoming version.,No,No,NA,NA,NA,NA,NA

1 cdmTableName cdmFieldName isRequired cdmDatatype userGuidance etlConventions isPrimaryKey isForeignKey fkTableName fkFieldName fkDomain fkClass unique DQ identifiers
142 measurement provider_id No integer The provider associated with measurement record, e.g. the provider who ordered the test or the provider who recorded the result. The ETL may need to make a choice as to which PROVIDER_ID to put here. Based on what is available this may or may not be different than the provider associated with the overall VISIT_OCCURRENCE record. For example the admitting vs attending physician on an EHR record. No Yes PROVIDER PROVIDER_ID NA NA NA
143 measurement visit_occurrence_id No integer The visit during which the Measurement occurred. Depending on the structure of the source data, this may have to be determined based on dates. If a MEASUREMENT_DATE occurs within the start and end date of a Visit it is a valid ETL choice to choose the VISIT_OCCURRENCE_ID from the visit that subsumes it, even if not explicitly stated in the data. While not required, an attempt should be made to locate the VISIT_OCCURRENCE_ID of the measurement record. If a measurement is related to a visit explicitly in the source data, it is possible that the result date of the Measurement falls outside of the bounds of the Visit dates. No Yes VISIT_OCCURRENCE VISIT_OCCURRENCE_ID NA NA NA
144 measurement visit_detail_id No integer The VISIT_DETAIL record during which the Measurement occurred. For example, if the Person was in the ICU at the time the VISIT_OCCURRENCE record would reflect the overall hospital stay and the VISIT_DETAIL record would reflect the ICU stay during the hospital visit. Same rules apply as for the VISIT_OCCURRENCE_ID. No Yes VISIT_DETAIL VISIT_DETAIL_ID NA NA NA
145 measurement measurement_source_value No varchar(50) This field houses the verbatim value from the source data representing the Measurement that occurred. For example, this could be an ICD10 or Read code. This code is mapped to a Standard Measurement Concept in the Standardized Vocabularies and the original code is stored here for reference. No No NA NA NA NA NA
146 measurement measurement_source_concept_id No integer This is the concept representing the MEASUREMENT_SOURCE_VALUE and may not necessarily be standard. This field is discouraged from use in analysis because it is not required to contain Standard Concepts that are used across the OHDSI community, and should only be used when Standard Concepts do not adequately represent the source detail for the Measurement necessary for a given analytic use case. Consider using MEASUREMENT_CONCEPT_ID instead to enable standardized analytics that can be consistent across the network. If the MEASUREMENT_SOURCE_VALUE is coded in the source data using an OMOP supported vocabulary put the concept id representing the source value here. No Yes CONCEPT CONCEPT_ID NA NA NA
147 measurement unit_source_value No varchar(50) This field houses the verbatim value from the source data representing the unit of the Measurement that occurred. This code is mapped to a Standard Condition Concept in the Standardized Vocabularies and the original code is stored here for reference. No No NA NA NA NA NA
148 measurement value_source_value No varchar(50) This field houses the verbatim result value of the Measurement from the source data . If both a continuous and categorical result are given in the source data such that both VALUE_AS_NUMBER and VALUE_AS_CONCEPT_ID are both included, store the verbatim value that was mapped to VALUE_AS_CONCEPT_ID here. No No NA NA NA NA NA

View File

@ -148,7 +148,7 @@ device_exposure,unit_source_value,No,varchar(50),"This field houses the verbatim
device_exposure,unit_source_concept_id,No,integer,"This is the concept representing the UNIT_SOURCE_VALUE and may not necessarily be standard. This field is discouraged from use in analysis because it is not required to contain Standard Concepts that are used across the OHDSI community, and should only be used when Standard Concepts do not adequately represent the source detail for the Unit necessary for a given analytic use case. Consider using UNIT_CONCEPT_ID instead to enable standardized analytics that can be consistent across the network.",If the UNIT_SOURCE_VALUE is coded in the source data using an OMOP supported vocabulary put the concept id representing the source value here.,No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA device_exposure,unit_source_concept_id,No,integer,"This is the concept representing the UNIT_SOURCE_VALUE and may not necessarily be standard. This field is discouraged from use in analysis because it is not required to contain Standard Concepts that are used across the OHDSI community, and should only be used when Standard Concepts do not adequately represent the source detail for the Unit necessary for a given analytic use case. Consider using UNIT_CONCEPT_ID instead to enable standardized analytics that can be consistent across the network.",If the UNIT_SOURCE_VALUE is coded in the source data using an OMOP supported vocabulary put the concept id representing the source value here.,No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA
measurement,measurement_id,Yes,integer,The unique key given to a Measurement record for a Person. Refer to the ETL for how duplicate Measurements during the same Visit were handled.,"Each instance of a measurement present in the source data should be assigned this unique key. In some cases, a person can have multiple records of the same measurement within the same visit. It is valid to keep these duplicates and assign them individual, unique, MEASUREMENT_IDs, though it is up to the ETL how they should be handled.",Yes,No,NA,NA,NA,NA,NA measurement,measurement_id,Yes,integer,The unique key given to a Measurement record for a Person. Refer to the ETL for how duplicate Measurements during the same Visit were handled.,"Each instance of a measurement present in the source data should be assigned this unique key. In some cases, a person can have multiple records of the same measurement within the same visit. It is valid to keep these duplicates and assign them individual, unique, MEASUREMENT_IDs, though it is up to the ETL how they should be handled.",Yes,No,NA,NA,NA,NA,NA
measurement,person_id,Yes,integer,The PERSON_ID of the Person for whom the Measurement is recorded. This may be a system generated code.,NA,No,Yes,PERSON,PERSON_ID,NA,NA,NA measurement,person_id,Yes,integer,The PERSON_ID of the Person for whom the Measurement is recorded. This may be a system generated code.,NA,No,Yes,PERSON,PERSON_ID,NA,NA,NA
measurement,measurement_concept_id,Yes,integer,"The MEASUREMENT_CONCEPT_ID field is recommended for primary use in analyses, and must be used for network studies.","The CONCEPT_ID that the MEASUREMENT_SOURCE_CONCEPT_ID maps to. Only records whose SOURCE_CONCEPT_IDs map to Standard Concepts with a domain of ""Measurement"" should go in this table.",No,Yes,CONCEPT,CONCEPT_ID,Measurement,NA,NA measurement,measurement_concept_id,Yes,integer,"The MEASUREMENT_CONCEPT_ID field is recommended for primary use in analyses, and must be used for network studies. This is the standard concept mapped from the source value which represents a measurement.",The CONCEPT_ID that the MEASUREMENT_SOURCE_VALUE maps to. Only records whose source values map to concepts with a domain of ÒMeasurementÓ should go in this table.,No,Yes,CONCEPT,CONCEPT_ID,Measurement,NA,NA
measurement,measurement_date,Yes,date,Use this date to determine the date of the measurement.,"If there are multiple dates in the source data associated with a record such as order_date, draw_date, and result_date, choose the one that is closest to the date the sample was drawn from the patient.",No,No,NA,NA,NA,NA,NA measurement,measurement_date,Yes,date,Use this date to determine the date of the measurement.,"If there are multiple dates in the source data associated with a record such as order_date, draw_date, and result_date, choose the one that is closest to the date the sample was drawn from the patient.",No,No,NA,NA,NA,NA,NA
measurement,measurement_datetime,No,datetime,NA,"This is not required, though it is in v6. If a source does not specify datetime the convention is to set the time to midnight (00:00:0000)",No,No,NA,NA,NA,NA,NA measurement,measurement_datetime,No,datetime,NA,"This is not required, though it is in v6. If a source does not specify datetime the convention is to set the time to midnight (00:00:0000)",No,No,NA,NA,NA,NA,NA
measurement,measurement_time,No,varchar(10),NA,This is present for backwards compatibility and will be deprecated in an upcoming version.,No,No,NA,NA,NA,NA,NA measurement,measurement_time,No,varchar(10),NA,This is present for backwards compatibility and will be deprecated in an upcoming version.,No,No,NA,NA,NA,NA,NA

1 cdmTableName cdmFieldName isRequired cdmDatatype userGuidance etlConventions isPrimaryKey isForeignKey fkTableName fkFieldName fkDomain fkClass unique DQ identifiers
148 measurement provider_id No integer The provider associated with measurement record, e.g. the provider who ordered the test or the provider who recorded the result. The ETL may need to make a choice as to which PROVIDER_ID to put here. Based on what is available this may or may not be different than the provider associated with the overall VISIT_OCCURRENCE record. For example the admitting vs attending physician on an EHR record. No Yes PROVIDER PROVIDER_ID NA NA NA
149 measurement visit_occurrence_id No integer The visit during which the Measurement occurred. Depending on the structure of the source data, this may have to be determined based on dates. If a MEASUREMENT_DATE occurs within the start and end date of a Visit it is a valid ETL choice to choose the VISIT_OCCURRENCE_ID from the visit that subsumes it, even if not explicitly stated in the data. While not required, an attempt should be made to locate the VISIT_OCCURRENCE_ID of the measurement record. If a measurement is related to a visit explicitly in the source data, it is possible that the result date of the Measurement falls outside of the bounds of the Visit dates. No Yes VISIT_OCCURRENCE VISIT_OCCURRENCE_ID NA NA NA
150 measurement visit_detail_id No integer The VISIT_DETAIL record during which the Measurement occurred. For example, if the Person was in the ICU at the time the VISIT_OCCURRENCE record would reflect the overall hospital stay and the VISIT_DETAIL record would reflect the ICU stay during the hospital visit. Same rules apply as for the VISIT_OCCURRENCE_ID. No Yes VISIT_DETAIL VISIT_DETAIL_ID NA NA NA
151 measurement measurement_source_value No varchar(50) This field houses the verbatim value from the source data representing the Measurement that occurred. For example, this could be an ICD10 or Read code. This code is mapped to a Standard Measurement Concept in the Standardized Vocabularies and the original code is stored here for reference. No No NA NA NA NA NA
152 measurement measurement_source_concept_id No integer This is the concept representing the MEASUREMENT_SOURCE_VALUE and may not necessarily be standard. This field is discouraged from use in analysis because it is not required to contain Standard Concepts that are used across the OHDSI community, and should only be used when Standard Concepts do not adequately represent the source detail for the Measurement necessary for a given analytic use case. Consider using MEASUREMENT_CONCEPT_ID instead to enable standardized analytics that can be consistent across the network. If the MEASUREMENT_SOURCE_VALUE is coded in the source data using an OMOP supported vocabulary put the concept id representing the source value here. No Yes CONCEPT CONCEPT_ID NA NA NA
153 measurement unit_source_value No varchar(50) This field houses the verbatim value from the source data representing the unit of the Measurement that occurred. This code is mapped to a Standard Condition Concept in the Standardized Vocabularies and the original code is stored here for reference. No No NA NA NA NA NA
154 measurement unit_source_concept_id No integer "This is the concept representing the UNIT_SOURCE_VALUE and may not necessarily be standard. This field is discouraged from use in analysis because it is not required to contain Standard Concepts that are used across the OHDSI community, and should only be used when Standard Concepts do not adequately represent the source detail for the Measurement necessary for a given analytic use case. Consider using UNIT_CONCEPT_ID instead to enable standardized analytics that can be consistent across the network." If the UNIT_SOURCE_VALUE is coded in the source data using an OMOP supported vocabulary put the concept id representing the source value here. No Yes CONCEPT CONCEPT_ID NA NA NA