From 4b96b13b55453d8ca34d8b9641b3f1641a8befb1 Mon Sep 17 00:00:00 2001 From: Clair Blacketer Date: Thu, 6 Mar 2025 11:48:31 -0500 Subject: [PATCH] closes #504 --- docs/cdm54.html | 5 +++-- inst/csv/OMOP_CDMv5.4_Field_Level.csv | 2 +- inst/csv/OMOP_CDMv6.0_Field_Level.csv | 2 +- 3 files changed, 5 insertions(+), 4 deletions(-) diff --git a/docs/cdm54.html b/docs/cdm54.html index d75f304..b7ba76c 100644 --- a/docs/cdm54.html +++ b/docs/cdm54.html @@ -3583,7 +3583,7 @@ Concept and are recorded in the following order of precedence: Marketed Product, Branded Pack, Clinical Pack, Branded Drug, Clinical Drug, Branded Drug Component, Clinical Drug Component, Branded Drug Form, Clinical Drug Form, and only if no other information is available -�Ingredient�. Note: If only the drug class is known, the DRUG_CONCEPT_ID +Ingredient. Note: If only the drug class is known, the DRUG_CONCEPT_ID field should contain 0. Accepted Concepts. @@ -5750,7 +5750,8 @@ from =. Operators are =, > and these concepts belong to the ‘Meas Value Operator’ domain. Accepted -Concepts. Leave it NULL if there’s an exact numeric value given +Concepts. The operator_concept_id explictly refers to the value of +the measurement. Leave it NULL if there’s an exact numeric value given (instead of putting ‘=’) or there’s no numeric value at all. diff --git a/inst/csv/OMOP_CDMv5.4_Field_Level.csv b/inst/csv/OMOP_CDMv5.4_Field_Level.csv index 2efd088..8c27091 100644 --- a/inst/csv/OMOP_CDMv5.4_Field_Level.csv +++ b/inst/csv/OMOP_CDMv5.4_Field_Level.csv @@ -153,7 +153,7 @@ measurement,measurement_date,Yes,date,Use this date to determine the date of the measurement,measurement_datetime,No,datetime,NA,"This is not required, though it is in v6. If a source does not specify datetime the convention is to set the time to midnight (00:00:0000)",No,No,NA,NA,NA,NA,NA measurement,measurement_time,No,varchar(10),NA,This is present for backwards compatibility and will be deprecated in an upcoming version.,No,No,NA,NA,NA,NA,NA measurement,measurement_type_concept_id,Yes,integer,"This field can be used to determine the provenance of the Measurement record, as in whether the measurement was from an EHR system, insurance claim, registry, or other sources.","Choose the MEASUREMENT_TYPE_CONCEPT_ID that best represents the provenance of the record, for example whether it came from an EHR record or billing claim. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Type+Concept&standardConcept=Standard&page=1&pageSize=15&query=). A more detailed explanation of each Type Concept can be found on the [vocabulary wiki](https://github.com/OHDSI/Vocabulary-v5.0/wiki/Vocab.-TYPE_CONCEPT).",No,Yes,CONCEPT,CONCEPT_ID,Type Concept,NA,NA -measurement,operator_concept_id,No,integer,"The meaning of Concept [4172703](https://athena.ohdsi.org/search-terms/terms/4172703) for '=' is identical to omission of a OPERATOR_CONCEPT_ID value. Since the use of this field is rare, it's important when devising analyses to not to forget testing for the content of this field for values different from =.","Operators are <, <=, =, >=, > and these concepts belong to the 'Meas Value Operator' domain. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Meas+Value+Operator&standardConcept=Standard&page=1&pageSize=15&query=). Leave it NULL if there's an exact numeric value given (instead of putting '=') or there's no numeric value at all.",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA +measurement,operator_concept_id,No,integer,"The meaning of Concept [4172703](https://athena.ohdsi.org/search-terms/terms/4172703) for '=' is identical to omission of a OPERATOR_CONCEPT_ID value. Since the use of this field is rare, it's important when devising analyses to not to forget testing for the content of this field for values different from =.","Operators are <, <=, =, >=, > and these concepts belong to the 'Meas Value Operator' domain. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Meas+Value+Operator&standardConcept=Standard&page=1&pageSize=15&query=). The operator_concept_id explictly refers to the value of the measurement. Leave it NULL if there's an exact numeric value given (instead of putting '=') or there's no numeric value at all.",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA measurement,value_as_number,No,float,"This is the numerical value of the Result of the Measurement, if available. Note that measurements such as blood pressures will be split into their component parts i.e. one record for systolic, one record for diastolic.",[Convention for negative values](https://ohdsi.github.io/Themis/negative_value_as_number.html),No,No,NA,NA,NA,NA,NA measurement,value_as_concept_id,No,integer,If the raw data gives a categorial result for measurements those values are captured and mapped to standard concepts in the 'Meas Value' domain.,"If there is no categorial result in the source data, set VALUE_AS_CONCEPT_ID to NULL, if there is a categorial result in a source data but without mapping, set VALUE_AS_CONCEPT_ID to 0, else map to a CONCEPT_ID.",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA measurement,unit_concept_id,No,integer,"At present, there isn't a prescribed unit for individual measurements, such as Hemoglobin A1C, meaning it's not obligatory to express these measurements as a percentage. UNIT_SOURCE_VALUES should be linked to a Standard Concept within the Unit domain that most accurately reflects the unit provided in the source data.","If the source data does not include units, set UNIT_CONCEPT_ID to NULL. If units are provided but not mapped, set UNIT_CONCEPT_ID to 0. Otherwise, map the units to a CONCEPT_ID. Remember that units are case-sensitive in vocabulary.",No,Yes,CONCEPT,CONCEPT_ID,Unit,NA,NA diff --git a/inst/csv/OMOP_CDMv6.0_Field_Level.csv b/inst/csv/OMOP_CDMv6.0_Field_Level.csv index 3b12542..15451c4 100644 --- a/inst/csv/OMOP_CDMv6.0_Field_Level.csv +++ b/inst/csv/OMOP_CDMv6.0_Field_Level.csv @@ -148,7 +148,7 @@ measurement,measurement_date,Yes,date,Use this date to determine the date of the measurement,measurement_datetime,No,datetime,NA,"This is not required, though it is in v6. If a source does not specify datetime the convention is to set the time to midnight (00:00:0000)",No,No,NA,NA,NA,NA,NA measurement,measurement_time,No,varchar(10),NA,This is present for backwards compatibility and will be deprecated in an upcoming version.,No,No,NA,NA,NA,NA,NA measurement,measurement_type_concept_id,Yes,integer,"This field can be used to determine the provenance of the Measurement record, as in whether the measurement was from an EHR system, insurance claim, registry, or other sources.","Choose the MEASUREMENT_TYPE_CONCEPT_ID that best represents the provenance of the record, for example whether it came from an EHR record or billing claim. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Type+Concept&standardConcept=Standard&page=1&pageSize=15&query=).",No,Yes,CONCEPT,CONCEPT_ID,Type Concept,NA,NA -measurement,operator_concept_id,No,integer,"The meaning of Concept [4172703](https://athena.ohdsi.org/search-terms/terms/4172703) for '=' is identical to omission of a OPERATOR_CONCEPT_ID value. Since the use of this field is rare, it's important when devising analyses to not to forget testing for the content of this field for values different from =.","Operators are <, <=, =, >=, > and these concepts belong to the 'Meas Value Operator' domain. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Meas+Value+Operator&standardConcept=Standard&page=1&pageSize=15&query=).",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA +measurement,operator_concept_id,No,integer,"The meaning of Concept [4172703](https://athena.ohdsi.org/search-terms/terms/4172703) for '=' is identical to omission of a OPERATOR_CONCEPT_ID value. Since the use of this field is rare, it's important when devising analyses to not to forget testing for the content of this field for values different from =.","The operator_concept_id explictly refers to the value of the measurement. Operators are <, <=, =, >=, > and these concepts belong to the 'Meas Value Operator' domain. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Meas+Value+Operator&standardConcept=Standard&page=1&pageSize=15&query=).",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA measurement,value_as_number,No,float,"This is the numerical value of the Result of the Measurement, if available. Note that measurements such as blood pressures will be split into their component parts i.e. one record for systolic, one record for diastolic.","If there is a negative value coming from the source, set the VALUE_AS_NUMBER to NULL, with the exception of the following Measurements (listed as LOINC codes):
- [1925-7](https://athena.ohdsi.org/search-terms/terms/3003396) Base excess in Arterial blood by calculation - [1927-3](https://athena.ohdsi.org/search-terms/terms/3002032) Base excess in Venous blood by calculation - [8632-2](https://athena.ohdsi.org/search-terms/terms/3006277) QRS-Axis - [11555-0](https://athena.ohdsi.org/search-terms/terms/3012501) Base excess in Blood by calculation - [1926-5](https://athena.ohdsi.org/search-terms/terms/3003129) Base excess in Capillary blood by calculation - [28638-5](https://athena.ohdsi.org/search-terms/terms/3004959) Base excess in Arterial cord blood by calculation [28639-3](https://athena.ohdsi.org/search-terms/terms/3007435) Base excess in Venous cord blood by calculation",No,No,NA,NA,NA,NA,NA measurement,value_as_concept_id,No,integer,If the raw data gives a categorial result for measurements those values are captured and mapped to standard concepts in the 'Meas Value' domain.,"If the raw data provides categorial results as well as continuous results for measurements, it is a valid ETL choice to preserve both values. The continuous value should go in the VALUE_AS_NUMBER field and the categorical value should be mapped to a standard concept in the 'Meas Value' domain and put in the VALUE_AS_CONCEPT_ID field. This is also the destination for the 'Maps to value' relationship.",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA measurement,unit_concept_id,No,integer,"There is currently no recommended unit for individual measurements, i.e. it is not mandatory to represent Hemoglobin a1C measurements as a percentage. UNIT_SOURCE_VALUES should be mapped to a Standard Concept in the Unit domain that best represents the unit as given in the source data.","There is no standardization requirement for units associated with MEASUREMENT_CONCEPT_IDs, however, it is the responsibility of the ETL to choose the most plausible unit.",No,Yes,CONCEPT,CONCEPT_ID,Unit,NA,NA