|
|
@ -164,7 +164,7 @@ measurement,visit_occurrence_id,No,integer,The visit during which the Measuremen
|
|
|
|
measurement,visit_detail_id,No,integer,"The VISIT_DETAIL record during which the Measurement occurred. For example, if the Person was in the ICU at the time the VISIT_OCCURRENCE record would reflect the overall hospital stay and the VISIT_DETAIL record would reflect the ICU stay during the hospital visit.",Same rules apply as for the VISIT_OCCURRENCE_ID.,No,Yes,VISIT_DETAIL,VISIT_DETAIL_ID,NA,NA,NA
|
|
|
|
measurement,visit_detail_id,No,integer,"The VISIT_DETAIL record during which the Measurement occurred. For example, if the Person was in the ICU at the time the VISIT_OCCURRENCE record would reflect the overall hospital stay and the VISIT_DETAIL record would reflect the ICU stay during the hospital visit.",Same rules apply as for the VISIT_OCCURRENCE_ID.,No,Yes,VISIT_DETAIL,VISIT_DETAIL_ID,NA,NA,NA
|
|
|
|
measurement,measurement_source_value,No,varchar(50),"This field houses the verbatim value from the source data representing the Measurement that occurred. For example, this could be an ICD10 or Read code.",This code is mapped to a Standard Measurement Concept in the Standardized Vocabularies and the original code is stored here for reference.,No,No,NA,NA,NA,NA,NA
|
|
|
|
measurement,measurement_source_value,No,varchar(50),"This field houses the verbatim value from the source data representing the Measurement that occurred. For example, this could be an ICD10 or Read code.",This code is mapped to a Standard Measurement Concept in the Standardized Vocabularies and the original code is stored here for reference.,No,No,NA,NA,NA,NA,NA
|
|
|
|
measurement,measurement_source_concept_id,No,integer,"This is the concept representing the MEASUREMENT_SOURCE_VALUE and may not necessarily be standard. This field is discouraged from use in analysis because it is not required to contain Standard Concepts that are used across the OHDSI community, and should only be used when Standard Concepts do not adequately represent the source detail for the Measurement necessary for a given analytic use case. Consider using MEASUREMENT_CONCEPT_ID instead to enable standardized analytics that can be consistent across the network.",If the MEASUREMENT_SOURCE_VALUE is coded in the source data using an OMOP supported vocabulary put the concept id representing the source value here.,No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA
|
|
|
|
measurement,measurement_source_concept_id,No,integer,"This is the concept representing the MEASUREMENT_SOURCE_VALUE and may not necessarily be standard. This field is discouraged from use in analysis because it is not required to contain Standard Concepts that are used across the OHDSI community, and should only be used when Standard Concepts do not adequately represent the source detail for the Measurement necessary for a given analytic use case. Consider using MEASUREMENT_CONCEPT_ID instead to enable standardized analytics that can be consistent across the network.",If the MEASUREMENT_SOURCE_VALUE is coded in the source data using an OMOP supported vocabulary put the concept id representing the source value here.,No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA
|
|
|
|
measurement,unit_source_value,No,varchar(50),This field houses the verbatim value from the source data representing the unit of the Measurement that occurred.,This code is mapped to a Standard Condition Concept in the Standardized Vocabularies and the original code is stored here for reference.,No,No,NA,NA,NA,NA,NA
|
|
|
|
measurement,unit_source_value,No,varchar(50),This field contains the exact value from the source data that represents the unit of measurement used.,This value corresponds to a standardized CONCEPT_ID found in UNIT_CONCEPT_ID and in the 'Unit' domain within the Standardized Vocabularies. The original code is retained here for reference purposes.,No,No,NA,NA,NA,NA,NA
|
|
|
|
measurement,unit_source_concept_id,No,integer,"""This is the concept representing the UNIT_SOURCE_VALUE and may not necessarily be standard. This field is discouraged from use in analysis because it is not required to contain Standard Concepts that are used across the OHDSI community, and should only be used when Standard Concepts do not adequately represent the source detail for the Measurement necessary for a given analytic use case. Consider using UNIT_CONCEPT_ID instead to enable standardized analytics that can be consistent across the network.""",If the UNIT_SOURCE_VALUE is coded in the source data using an OMOP supported vocabulary put the concept id representing the source value here.,No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA
|
|
|
|
measurement,unit_source_concept_id,No,integer,"""This is the concept representing the UNIT_SOURCE_VALUE and may not necessarily be standard. This field is discouraged from use in analysis because it is not required to contain Standard Concepts that are used across the OHDSI community, and should only be used when Standard Concepts do not adequately represent the source detail for the Measurement necessary for a given analytic use case. Consider using UNIT_CONCEPT_ID instead to enable standardized analytics that can be consistent across the network.""",If the UNIT_SOURCE_VALUE is coded in the source data using an OMOP supported vocabulary put the concept id representing the source value here.,No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA
|
|
|
|
measurement,value_source_value,No,varchar(50),This field houses the verbatim result value of the Measurement from the source data .,"If both a continuous and categorical result are given in the source data such that both VALUE_AS_NUMBER and VALUE_AS_CONCEPT_ID are both included, store the verbatim value that was mapped to VALUE_AS_CONCEPT_ID here.",No,No,NA,NA,NA,NA,NA
|
|
|
|
measurement,value_source_value,No,varchar(50),This field houses the verbatim result value of the Measurement from the source data .,"If both a continuous and categorical result are given in the source data such that both VALUE_AS_NUMBER and VALUE_AS_CONCEPT_ID are both included, store the verbatim value that was mapped to VALUE_AS_CONCEPT_ID here.",No,No,NA,NA,NA,NA,NA
|
|
|
|
measurement,measurement_event_id,No,integer,"If the Measurement record is related to another record in the database, this field is the primary key of the linked record.","Put the primary key of the linked record, if applicable, here.",No,No,NA,NA,NA,NA,NA
|
|
|
|
measurement,measurement_event_id,No,integer,"If the Measurement record is related to another record in the database, this field is the primary key of the linked record.","Put the primary key of the linked record, if applicable, here.",No,No,NA,NA,NA,NA,NA
|
|
|
|