value_as_concept_id null

closes #641
This commit is contained in:
Clair Blacketer 2024-04-17 21:02:29 -04:00
parent 201204fdfb
commit 98bea2c6f5
2 changed files with 2 additions and 2 deletions

View File

@ -149,7 +149,7 @@ measurement,measurement_time,No,varchar(10),NA,This is present for backwards com
measurement,measurement_type_concept_id,Yes,integer,"This field can be used to determine the provenance of the Measurement record, as in whether the measurement was from an EHR system, insurance claim, registry, or other sources.","Choose the MEASUREMENT_TYPE_CONCEPT_ID that best represents the provenance of the record, for example whether it came from an EHR record or billing claim. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Type+Concept&standardConcept=Standard&page=1&pageSize=15&query=).",No,Yes,CONCEPT,CONCEPT_ID,Type Concept,NA,NA measurement,measurement_type_concept_id,Yes,integer,"This field can be used to determine the provenance of the Measurement record, as in whether the measurement was from an EHR system, insurance claim, registry, or other sources.","Choose the MEASUREMENT_TYPE_CONCEPT_ID that best represents the provenance of the record, for example whether it came from an EHR record or billing claim. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Type+Concept&standardConcept=Standard&page=1&pageSize=15&query=).",No,Yes,CONCEPT,CONCEPT_ID,Type Concept,NA,NA
measurement,operator_concept_id,No,integer,"The meaning of Concept [4172703](https://athena.ohdsi.org/search-terms/terms/4172703) for '=' is identical to omission of a OPERATOR_CONCEPT_ID value. Since the use of this field is rare, it's important when devising analyses to not to forget testing for the content of this field for values different from =.","Operators are <, <=, =, >=, > and these concepts belong to the 'Meas Value Operator' domain. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Meas+Value+Operator&standardConcept=Standard&page=1&pageSize=15&query=). Leave it NULL if there's an exact numeric value given (instead of putting '=') or there's no numeric value at all.",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA measurement,operator_concept_id,No,integer,"The meaning of Concept [4172703](https://athena.ohdsi.org/search-terms/terms/4172703) for '=' is identical to omission of a OPERATOR_CONCEPT_ID value. Since the use of this field is rare, it's important when devising analyses to not to forget testing for the content of this field for values different from =.","Operators are <, <=, =, >=, > and these concepts belong to the 'Meas Value Operator' domain. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Meas+Value+Operator&standardConcept=Standard&page=1&pageSize=15&query=). Leave it NULL if there's an exact numeric value given (instead of putting '=') or there's no numeric value at all.",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA
measurement,value_as_number,No,float,"This is the numerical value of the Result of the Measurement, if available. Note that measurements such as blood pressures will be split into their component parts i.e. one record for systolic, one record for diastolic.",[Convention for negative values](https://ohdsi.github.io/Themis/negative_value_as_number.html),No,No,NA,NA,NA,NA,NA measurement,value_as_number,No,float,"This is the numerical value of the Result of the Measurement, if available. Note that measurements such as blood pressures will be split into their component parts i.e. one record for systolic, one record for diastolic.",[Convention for negative values](https://ohdsi.github.io/Themis/negative_value_as_number.html),No,No,NA,NA,NA,NA,NA
measurement,value_as_concept_id,No,integer,If the raw data gives a categorial result for measurements those values are captured and mapped to standard concepts in the 'Meas Value' domain.,"If the raw data provides categorial results as well as continuous results for measurements, it is a valid ETL choice to preserve both values. The continuous value should go in the VALUE_AS_NUMBER field and the categorical value should be mapped to a standard concept in the 'Meas Value' domain and put in the VALUE_AS_CONCEPT_ID field. This is also the destination for the 'Maps to value' relationship. If there's no categorial result in a source_data, set value_as_concept_id to NULL, if there is a categorial result in a source_data but without mapping, set value_as_concept_id to 0.",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA measurement,value_as_concept_id,No,integer,If the raw data gives a categorial result for measurements those values are captured and mapped to standard concepts in the 'Meas Value' domain.,"If there is no categorial result in the source data, set VALUE_AS_CONCEPT_ID to NULL, if there is a categorial result in a source data but without mapping, set VALUE_AS_CONCEPT_ID to 0, else map to a CONCEPT_ID.",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA
measurement,unit_concept_id,No,integer,"At present, there isn't a prescribed unit for individual measurements, such as Hemoglobin A1C, meaning it's not obligatory to express these measurements as a percentage. UNIT_SOURCE_VALUES should be linked to a Standard Concept within the Unit domain that most accurately reflects the unit provided in the source data.","If the source data does not include units, set UNIT_CONCEPT_ID to NULL. If units are provided but not mapped, set UNIT_CONCEPT_ID to 0. Otherwise, map the units to a CONCEPT_ID. Remember that units are case-sensitive in vocabulary.",No,Yes,CONCEPT,CONCEPT_ID,Unit,NA,NA measurement,unit_concept_id,No,integer,"At present, there isn't a prescribed unit for individual measurements, such as Hemoglobin A1C, meaning it's not obligatory to express these measurements as a percentage. UNIT_SOURCE_VALUES should be linked to a Standard Concept within the Unit domain that most accurately reflects the unit provided in the source data.","If the source data does not include units, set UNIT_CONCEPT_ID to NULL. If units are provided but not mapped, set UNIT_CONCEPT_ID to 0. Otherwise, map the units to a CONCEPT_ID. Remember that units are case-sensitive in vocabulary.",No,Yes,CONCEPT,CONCEPT_ID,Unit,NA,NA
measurement,range_low,No,float,Ranges have the same unit as the VALUE_AS_NUMBER. These ranges are provided by the source and should remain NULL if not given.,If reference ranges for upper and lower limit of normal as provided (typically by a laboratory) these are stored in the RANGE_HIGH and RANGE_LOW fields. This should be set to NULL if not provided.,No,No,NA,NA,NA,NA,NA measurement,range_low,No,float,Ranges have the same unit as the VALUE_AS_NUMBER. These ranges are provided by the source and should remain NULL if not given.,If reference ranges for upper and lower limit of normal as provided (typically by a laboratory) these are stored in the RANGE_HIGH and RANGE_LOW fields. This should be set to NULL if not provided.,No,No,NA,NA,NA,NA,NA
measurement,range_high,No,float,Ranges have the same unit as the VALUE_AS_NUMBER. These ranges are provided by the source and should remain NULL if not given.,If reference ranges for upper and lower limit of normal as provided (typically by a laboratory) these are stored in the RANGE_HIGH and RANGE_LOW fields. This should be set to NULL if not provided.,No,No,NA,NA,NA,NA,NA measurement,range_high,No,float,Ranges have the same unit as the VALUE_AS_NUMBER. These ranges are provided by the source and should remain NULL if not given.,If reference ranges for upper and lower limit of normal as provided (typically by a laboratory) these are stored in the RANGE_HIGH and RANGE_LOW fields. This should be set to NULL if not provided.,No,No,NA,NA,NA,NA,NA

1 cdmTableName cdmFieldName isRequired cdmDatatype userGuidance etlConventions isPrimaryKey isForeignKey fkTableName fkFieldName fkDomain fkClass unique DQ identifiers
149 observation observation_id Yes integer The unique key given to an Observation record for a Person. Refer to the ETL for how duplicate Observations during the same Visit were handled. Each instance of an observation present in the source data should be assigned this unique key. Yes No NA NA NA NA NA
150 observation person_id Yes integer The PERSON_ID of the Person for whom the Observation is recorded. This may be a system generated code. NA No Yes PERSON PERSON_ID NA NA NA
151 observation observation_concept_id Yes integer The OBSERVATION_CONCEPT_ID field is recommended for primary use in analyses, and must be used for network studies. The CONCEPT_ID that the OBSERVATION_SOURCE_CONCEPT_ID maps to. There is no specified domain that the Concepts in this table must adhere to. The only rule is that records with Concepts in the Condition, Procedure, Drug, Measurement, or Device domains MUST go to the corresponding table. No Yes CONCEPT CONCEPT_ID NA NA NA
152 observation observation_date Yes date The date of when the Observation was obtained. Depending on what the Observation represents this could be the date of a lab test, the date of a survey, or the date a patient's family history was taken. For some observations the ETL may need to make a choice as to which date to choose. No No NA NA NA NA NA
153 observation observation_datetime No datetime NA If no time is given set to midnight (00:00:00). No No NA NA NA NA NA
154 observation observation_type_concept_id Yes integer This field can be used to determine the provenance of the Observation record, as in whether the measurement was from an EHR system, insurance claim, registry, or other sources. Choose the OBSERVATION_TYPE_CONCEPT_ID that best represents the provenance of the record, for example whether it came from an EHR record or billing claim. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Type+Concept&standardConcept=Standard&page=1&pageSize=15&query=). No Yes CONCEPT CONCEPT_ID Type Concept NA NA
155 observation value_as_number No float This is the numerical value of the Result of the Observation, if applicable and available. It is not expected that all Observations will have numeric results, rather, this field is here to house values should they exist. NA No No NA NA NA NA NA

View File

@ -155,7 +155,7 @@ measurement,measurement_time,No,varchar(10),NA,This is present for backwards com
measurement,measurement_type_concept_id,Yes,integer,"This field can be used to determine the provenance of the Measurement record, as in whether the measurement was from an EHR system, insurance claim, registry, or other sources.","Choose the MEASUREMENT_TYPE_CONCEPT_ID that best represents the provenance of the record, for example whether it came from an EHR record or billing claim. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Type+Concept&standardConcept=Standard&page=1&pageSize=15&query=). A more detailed explanation of each Type Concept can be found on the [vocabulary wiki](https://github.com/OHDSI/Vocabulary-v5.0/wiki/Vocab.-TYPE_CONCEPT).",No,Yes,CONCEPT,CONCEPT_ID,Type Concept,NA,NA measurement,measurement_type_concept_id,Yes,integer,"This field can be used to determine the provenance of the Measurement record, as in whether the measurement was from an EHR system, insurance claim, registry, or other sources.","Choose the MEASUREMENT_TYPE_CONCEPT_ID that best represents the provenance of the record, for example whether it came from an EHR record or billing claim. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Type+Concept&standardConcept=Standard&page=1&pageSize=15&query=). A more detailed explanation of each Type Concept can be found on the [vocabulary wiki](https://github.com/OHDSI/Vocabulary-v5.0/wiki/Vocab.-TYPE_CONCEPT).",No,Yes,CONCEPT,CONCEPT_ID,Type Concept,NA,NA
measurement,operator_concept_id,No,integer,"The meaning of Concept [4172703](https://athena.ohdsi.org/search-terms/terms/4172703) for '=' is identical to omission of a OPERATOR_CONCEPT_ID value. Since the use of this field is rare, it's important when devising analyses to not to forget testing for the content of this field for values different from =.","Operators are <, <=, =, >=, > and these concepts belong to the 'Meas Value Operator' domain. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Meas+Value+Operator&standardConcept=Standard&page=1&pageSize=15&query=). Leave it NULL if there's an exact numeric value given (instead of putting '=') or there's no numeric value at all.",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA measurement,operator_concept_id,No,integer,"The meaning of Concept [4172703](https://athena.ohdsi.org/search-terms/terms/4172703) for '=' is identical to omission of a OPERATOR_CONCEPT_ID value. Since the use of this field is rare, it's important when devising analyses to not to forget testing for the content of this field for values different from =.","Operators are <, <=, =, >=, > and these concepts belong to the 'Meas Value Operator' domain. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Meas+Value+Operator&standardConcept=Standard&page=1&pageSize=15&query=). Leave it NULL if there's an exact numeric value given (instead of putting '=') or there's no numeric value at all.",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA
measurement,value_as_number,No,float,"This is the numerical value of the Result of the Measurement, if available. Note that measurements such as blood pressures will be split into their component parts i.e. one record for systolic, one record for diastolic.",[Convention for negative values](https://ohdsi.github.io/Themis/negative_value_as_number.html),No,No,NA,NA,NA,NA,NA measurement,value_as_number,No,float,"This is the numerical value of the Result of the Measurement, if available. Note that measurements such as blood pressures will be split into their component parts i.e. one record for systolic, one record for diastolic.",[Convention for negative values](https://ohdsi.github.io/Themis/negative_value_as_number.html),No,No,NA,NA,NA,NA,NA
measurement,value_as_concept_id,No,integer,If the raw data gives a categorial result for measurements those values are captured and mapped to standard concepts in the 'Meas Value' domain.,"If the raw data provides categorial results as well as continuous results for measurements, it is a valid ETL choice to preserve both values. The continuous value should go in the VALUE_AS_NUMBER field and the categorical value should be mapped to a standard concept in the 'Meas Value' domain and put in the VALUE_AS_CONCEPT_ID field. This is also the destination for the 'Maps to value' relationship. If there's no categorial result in a source_data, set value_as_concept_id to NULL, if there is a categorial result in a source_data but without mapping, set value_as_concept_id to 0.",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA measurement,value_as_concept_id,No,integer,If the raw data gives a categorial result for measurements those values are captured and mapped to standard concepts in the 'Meas Value' domain.,"If there is no categorial result in the source data, set VALUE_AS_CONCEPT_ID to NULL, if there is a categorial result in a source data but without mapping, set VALUE_AS_CONCEPT_ID to 0, else map to a CONCEPT_ID.",No,Yes,CONCEPT,CONCEPT_ID,NA,NA,NA
measurement,unit_concept_id,No,integer,"At present, there isn't a prescribed unit for individual measurements, such as Hemoglobin A1C, meaning it's not obligatory to express these measurements as a percentage. UNIT_SOURCE_VALUES should be linked to a Standard Concept within the Unit domain that most accurately reflects the unit provided in the source data.","If the source data does not include units, set UNIT_CONCEPT_ID to NULL. If units are provided but not mapped, set UNIT_CONCEPT_ID to 0. Otherwise, map the units to a CONCEPT_ID. Remember that units are case-sensitive in vocabulary.",No,Yes,CONCEPT,CONCEPT_ID,Unit,NA,NA measurement,unit_concept_id,No,integer,"At present, there isn't a prescribed unit for individual measurements, such as Hemoglobin A1C, meaning it's not obligatory to express these measurements as a percentage. UNIT_SOURCE_VALUES should be linked to a Standard Concept within the Unit domain that most accurately reflects the unit provided in the source data.","If the source data does not include units, set UNIT_CONCEPT_ID to NULL. If units are provided but not mapped, set UNIT_CONCEPT_ID to 0. Otherwise, map the units to a CONCEPT_ID. Remember that units are case-sensitive in vocabulary.",No,Yes,CONCEPT,CONCEPT_ID,Unit,NA,NA
measurement,range_low,No,float,Ranges have the same unit as the VALUE_AS_NUMBER. These ranges are provided by the source and should remain NULL if not given.,If reference ranges for upper and lower limit of normal as provided (typically by a laboratory) these are stored in the RANGE_HIGH and RANGE_LOW fields. This should be set to NULL if not provided.,No,No,NA,NA,NA,NA,NA measurement,range_low,No,float,Ranges have the same unit as the VALUE_AS_NUMBER. These ranges are provided by the source and should remain NULL if not given.,If reference ranges for upper and lower limit of normal as provided (typically by a laboratory) these are stored in the RANGE_HIGH and RANGE_LOW fields. This should be set to NULL if not provided.,No,No,NA,NA,NA,NA,NA
measurement,range_high,No,float,Ranges have the same unit as the VALUE_AS_NUMBER. These ranges are provided by the source and should remain NULL if not given.,If reference ranges for upper and lower limit of normal as provided (typically by a laboratory) these are stored in the RANGE_HIGH and RANGE_LOW fields. This should be set to NULL if not provided.,No,No,NA,NA,NA,NA,NA measurement,range_high,No,float,Ranges have the same unit as the VALUE_AS_NUMBER. These ranges are provided by the source and should remain NULL if not given.,If reference ranges for upper and lower limit of normal as provided (typically by a laboratory) these are stored in the RANGE_HIGH and RANGE_LOW fields. This should be set to NULL if not provided.,No,No,NA,NA,NA,NA,NA

1 cdmTableName cdmFieldName isRequired cdmDatatype userGuidance etlConventions isPrimaryKey isForeignKey fkTableName fkFieldName fkDomain fkClass unique DQ identifiers
155 measurement value_source_value No varchar(50) This field houses the verbatim result value of the Measurement from the source data . If both a continuous and categorical result are given in the source data such that both VALUE_AS_NUMBER and VALUE_AS_CONCEPT_ID are both included, store the verbatim value that was mapped to VALUE_AS_CONCEPT_ID here. No No NA NA NA NA NA
156 measurement measurement_event_id No integer If the Measurement record is related to another record in the database, this field is the primary key of the linked record. Put the primary key of the linked record, if applicable, here. No No NA NA NA NA NA
157 measurement meas_event_field_concept_id No integer If the Measurement record is related to another record in the database, this field is the CONCEPT_ID that identifies which table the primary key of the linked record came from. Put the CONCEPT_ID that identifies which table and field the MEASUREMENT_EVENT_ID came from. No Yes CONCEPT CONCEPT_ID NA NA NA
158 observation observation_id Yes integer The unique key given to an Observation record for a Person. Refer to the ETL for how duplicate Observations during the same Visit were handled. Each instance of an observation present in the source data should be assigned this unique key. Yes No NA NA NA NA NA
159 observation person_id Yes integer The PERSON_ID of the Person for whom the Observation is recorded. This may be a system generated code. NA No Yes PERSON PERSON_ID NA NA NA
160 observation observation_concept_id Yes integer The OBSERVATION_CONCEPT_ID field is recommended for primary use in analyses, and must be used for network studies. The CONCEPT_ID that the OBSERVATION_SOURCE_CONCEPT_ID maps to. There is no specified domain that the Concepts in this table must adhere to. The only rule is that records with Concepts in the Condition, Procedure, Drug, Measurement, or Device domains MUST go to the corresponding table. No Yes CONCEPT CONCEPT_ID NA NA NA
161 observation observation_date Yes date The date of when the Observation was obtained. Depending on what the Observation represents this could be the date of a lab test, the date of a survey, or the date a patient's family history was taken. For some observations the ETL may need to make a choice as to which date to choose. No No NA NA NA NA NA