Updated DEVICE_EXPOSURE (markdown)
parent
17ca45a150
commit
8794f07d31
|
@ -1,7 +1,7 @@
|
||||||
The device exposure domain captures information about a person’s exposure to a foreign physical object or instrument that which is used for diagnostic or therapeutic purposes through a mechanism beyond chemical action. Devices include implantable objects (e.g. pacemakers, stents, artificial joints), medical equipment and supplies (e.g. bandages, crutches, syringes), other instruments used in medical procedures (e.g. sutures, defibrillators) and material used in clinical care (e.g. adhesives, body material, dental material, surgical material).
|
The device exposure domain captures information about a person’s exposure to a foreign physical object or instrument that which is used for diagnostic or therapeutic purposes through a mechanism beyond chemical action. Devices include implantable objects (e.g. pacemakers, stents, artificial joints), medical equipment and supplies (e.g. bandages, crutches, syringes), other instruments used in medical procedures (e.g. sutures, defibrillators) and material used in clinical care (e.g. adhesives, body material, dental material, surgical material).
|
||||||
|
|
||||||
Field|Required|Type|Description
|
Field|Required|Type|Description
|
||||||
:----|:----|:-----|:-----
|
:------------------------------|:--------|:-----|:--------------------------------------------
|
||||||
|device_exposure_id|Yes|integer|A system-generated unique identifier for each Device Exposure.|
|
|device_exposure_id|Yes|integer|A system-generated unique identifier for each Device Exposure.|
|
||||||
|person_id|Yes|integer|A foreign key identifier to the Person who is subjected to the Device. The demographic details of that person are stored in the Person table.|
|
|person_id|Yes|integer|A foreign key identifier to the Person who is subjected to the Device. The demographic details of that person are stored in the Person table.|
|
||||||
|device_concept_id|Yes|integer|A foreign key that refers to a Standard Concept identifier in the Standardized Vocabularies for the Device concept.|
|
|device_concept_id|Yes|integer|A foreign key that refers to a Standard Concept identifier in the Standardized Vocabularies for the Device concept.|
|
||||||
|
@ -22,6 +22,6 @@ Field|Required|Type|Description
|
||||||
* The distinction between Devices or supplies and procedures are sometimes blurry, but the former are physical objects while the latter are actions, often to apply a Device or supply.
|
* The distinction between Devices or supplies and procedures are sometimes blurry, but the former are physical objects while the latter are actions, often to apply a Device or supply.
|
||||||
* For medical devices that are regulated by the FDA, if a Unique Device Identification (UDI) is provided if available in the data source, and is recorded in the unique_device_id field.
|
* For medical devices that are regulated by the FDA, if a Unique Device Identification (UDI) is provided if available in the data source, and is recorded in the unique_device_id field.
|
||||||
* Valid Device Concepts belong to the "Device" domain. The Concepts of this domain are derived from the DI portion of a UDI or based on other source vocabularies, like HCPCS.
|
* Valid Device Concepts belong to the "Device" domain. The Concepts of this domain are derived from the DI portion of a UDI or based on other source vocabularies, like HCPCS.
|
||||||
* A Device Type is assigned to each Device Exposure to track from what source the information was drawn or inferred. The valid domain_id for these Concepts is “Device Type”.
|
* A Device Type is assigned to each Device Exposure to track from what source the information was drawn or inferred. The valid domain_id for these Concepts is "Device Type".
|
||||||
* The Visit during which the Device was first used is recorded through a reference to the VISIT_OCCURRENCE table. This information is not always available.
|
* The Visit during which the Device was first used is recorded through a reference to the VISIT_OCCURRENCE table. This information is not always available.
|
||||||
* The Provider exposing the patient to the Device is recorded through a reference to the PROVIDER table. This information is not always available.
|
* The Provider exposing the patient to the Device is recorded through a reference to the PROVIDER table. This information is not always available.
|